Project: Column-Fire Logo
Project no:
Author:

Project data

Project dataColumn-Fire
Date12/7/2022
Design codeEN

Geometry


Analyzed members

AM1

PropertyValue
NameAM1
MembersM2
Cross-sectionRectangle 400, 250
Length8.00 m
ey0 mm
ez0 mm
Begin(0.00; 0.00; 0.00) m
End(0.00; 0.00; 8.00) m
Member typeColumn 1
Support Begin■ X | ■ Y | ■ Z | □ Rx | □ Ry | ■ Rz
Support End□ X | ■ Y | ■ Z | □ Rx | □ Ry | □ Rz

Related members

Member type

Column 1

PropertyValue
Member typeColumn
NameColumn 1
CarbonationXC3
ChloridesXD1
Chlorides from seaNot allowed
Freeze/Thaw attackNot allowed
Chemical attackNot allowed
Effect consideredIsolatedMember
Geometric imperfectionsBothDirections
Method of analysisNominalCurvature
Factor c to y axisUserDefined
cy9.86960440108936
Factor c to z axisUserDefined
cz9.86960440108936

Cross-section

Rectangle 400, 250, Material: C25/30
Rectangle 400, 250, Material: C25/30

Fire design data (list of Fire exposure data)

Fire curve: Standard fire curve ISO 834 (EN 1991-1-2)

EXP1

Members
Fire resistance class
Concrete moisture
[%]
Definition along the length
Initial member temperature
[°C]
AM1 R90 1.5 Whole length 20
Rectangle 400, 250
Rectangle 400, 250

Loading

LC1

Line load

Member
Begin
[m]
End
[m]
X
[kN/m]
Y
[kN/m]
Z
[kN/m]
Location
Width
[mm]
Ey
[mm]
AM1 0.00 8.00 0.0 0.0 -2.0 Member axis 0 0

Point load

Member
N
[kN]
Vy
[kN]
Vz
[kN]
Mx
[kN]
My
[kN]
Mz
[kN]
AM1 / 1.00 -110.0 0.0 0.0 0.0 0.0 0.0

Fire design

Results - Materially non-linear analysis (MNA)

Load bearing resistance of the shear reinforcement is not checked by the GMNA. For the code-check of the shear reinforcement, run the Linear analysis.

Overall


ULS strength

Detailed concrete strength results

Members
LE
Position X
[m]
σc
[MPa]
σc,lim
[MPa]
σcc,lim
[%]
εc
[1e-4]
εc,lim
[1e-4]
εcc,lim
[%]
Check
AM1 LE1 3.81 -3.6 -7.2 50.2 54.2 -351.6 24.4 OK

Detailed reinforcement strength results

Members
LE
Position X
[m]
σs
[MPa]
σs,lim
[MPa]
σss,lim
[%]
εs
[1e-4]
εs,lim
[1e-4]
εss,lim
[%]
Check
AM1 LE1 7.99 218.9 487.1 44.9 68.7 1500.0 1.1 OK

Results - Geometrically and materially non-linear analysis (GMNIA)

Load bearing resistance of the shear reinforcement is not checked by the GMNA. For the code-check of the shear reinforcement, run the Linear analysis.

Overall


ULS strength

Detailed concrete strength results

Members
LE
Position X
[m]
σc
[MPa]
σc,lim
[MPa]
σcc,lim
[%]
εc
[1e-4]
εc,lim
[1e-4]
εcc,lim
[%]
Check
AM1 LE1 3.81 -4.4 -7.4 59.7 36.8 -351.6 29.4 OK

Detailed reinforcement strength results

Members
LE
Position X
[m]
σs
[MPa]
σs,lim
[MPa]
σss,lim
[%]
εs
[1e-4]
εs,lim
[1e-4]
εss,lim
[%]
Check
AM1 LE1 1.56 243.7 487.1 50.0 72.7 1500.0 1.4 OK

Symbol explanation

Symbol
Explanation
Check Result of the check

Software info

Application IDEA StatiCa Member
Version 22.1.2.1391
Developed by IDEA StatiCa